Multiparameter Meters

Bante903 Benchtop pH/Dissolved Oxygen Meter

High-precision benchtop pH dissolved oxygen meter provides accurate measurements of pH, ORP and dissolved oxygen, suitable for laboratory applications.

Features:
pH
• 1 to 5 points calibration with automatic recognition for USA, NIST and DIN buffers.
• Automatic electrode diagnosis shows the pH slope and zero offset.

pH Dissolved Oxygen Meter

ORP
• 1 point offset calibration allows adjusting the displayed value to a known standard.
• Relative and absolute millivolt modes ensure the reliable ORP measurements.

Dissolved Oxygen
• 1 or 2 points calibration using the air-saturated water or zero oxygen solution.
• Salinity and barometric pressure compensations eliminate measurement errors.

pH Dissolved Oxygen Meter

Other Features
• Automatic temperature compensation ensures accurate readings over the entire range.
• Auto-read function senses and locks the measurement endpoint.
• Calibration due alarm reminds user to calibrate the meter regularly.
• Setup menu allows setting the number of calibration points, stability criteria, temperature unit,
  date and time, auto-power off, etc.
• Reset function automatically restores all settings to the factory defaults.
• Expanded memory stores or recalls up to 500 data sets.
• USB communication interface enables easy data transfer to a PC.
• DAS software is capable of receiving data, recording measurements at specified intervals,
  exporting data to Excel.

   Model


Bante903

   pH



   Range


-2.000 to 20.000 pH

   Resolution


0.001 / 0.01 / 0.1, selectable

   Accuracy


±0.002 pH

   Calibration


1 to 5 points

   pH Buffer Options


USA / NIST / DIN / 2 custom buffers

   ORP



   Range


-1999.9 to 1999.9 mV

   Resolution


0.1 / 1, selectable

   Accuracy


±0.2 mV

   Calibration


1 point

   Measurement Modes


Relative / Absolute mV

   Dissolved Oxygen



   Range


0.00 to 20.00 mg/L / 0.0 to 200.0 % saturation

   Resolution


0.01 / 0.1, selectable

   Accuracy


±0.2 mg/L / ±2.0 %

   Calibration


1 or 2 points

   Pressure Correction


60.0 to 112.5 kPa / 450 to 850 mmHg, manual

   Salinity Correction


0.0 to 50.0 g/L, manual

   Temperature



   Range


0 to 105°C / 32 to 221°F

   Resolution


0.1

   Accuracy


±0.5°C / ±0.9°F

   Calibration


1 point

   Calibration Range


Reading ±10°C/°F

   Other Specifications



   Temperature Compensation


0 to 100°C / 32 to 212°F, manual or automatic

   Hold Function


Manual / Auto-read measurement endpoint

   Stability Criteria


Low / High

   Calibration Due Alarm


1 to 31 days or off

   Memory


Stores up to 500 data sets

   Output


USB communication interface

   Connector


BNC, 6-pin mini-DIN, 3.5 mm jack socket

   Display


Custom LCD (125 × 100 mm)

   Power Supply


5V DC power adapter

   Environmental Conditions


0 to 50°C / 32 to 122°F, relative humidity < 80%

   Dimensions


210 × 188 × 60 mm

   Weight


1.5 kg

   Ordering Code

Meter Includes

   Bante903-CN

E201-BNC pH electrode

DO100 dissolved oxygen electrode

TP-10K temperature probe

pH 4.01, 7.00, 10.01 buffer reagents

DO electrolyte solution

DO membrane cap

USB cable

5V DC power adapter

   Bante903-UK

   

P11 glass pH electrode

DO100 dissolved oxygen electrode

TP-10K temperature probe

pH 4.01, 7.00, 10.01 buffer reagents

DO electrolyte solution

DO membrane cap

USB cable

5V DC power adapter

Items Description
E201-BNC pH Electrode For measuring general samples
E202-BNC pH Electrode For measuring semisolid and gel samples
P11 pH Electrode For measuring mildly corrosive samples
P11-LiCl pH Electrode For measuring non-aqueous samples
P11-HA pH Electrode For measuring high alkalinity samples
P13 pH Electrode For measuring micro-volume samples
P15 pH Electrode For measuring low conductivity samples
P16 pH Electrode For measuring Tris-buffered samples
P19 pH Electrode For piercing and measuring soft solids
E504 ORP Electrode For measuring oxidation-reduction potential
DO100 Dissolved Oxygen Electrode For measuring dissolved oxygen levels in water
TP-10K Temperature Probe For temperature compensation and measurement
pH Buffer Solutions For calibrating pH electrode
ORP Standard Solution For calibrating ORP electrode
Zero Oxygen Solution For calibrating dissolved oxygen electrode
DO Electrolyte Solution For filling dissolved oxygen electrode

   Ordering Code

Dimensions and Weights

   Bante903-CN

30 × 25 × 20 cm, 1.7 kg

   Bante903-UK

30 × 25 × 20 cm, 1.7 kg