Multiparameter Meters
Bante904P Portable Conductivity/Dissolved Oxygen Meter
High-performance multiparameter water quality meter contains 5 measurement modes, suitable for measuring conductivity, TDS, salinity, resistivity and dissolved oxygen.
Conductivity/TDS/Salinity/Resistivity Modes:
• Portable multiparameter water quality meter is equipped with a backlit LCD display.
• 1 to 5 points calibration with automatic recognition for conductivity standards.
• Selectable cell constant (K=0.1/1/10), reference temperature (20/25°C), TDS factor, linear and
pure water compensations, seawater and practical salinity measurement modes.
Dissolved Oxygen Mode:
• 1 or 2 points calibration using the air-saturated water or zero oxygen solution.
• Salinity and barometric pressure compensations eliminate the measurement errors.
Other Features:
• Automatic temperature compensation ensures accurate readings over the entire range.
• Auto-read function senses and locks the measurement endpoint.
• Calibration due alarm reminds the user to calibrate the meter regularly.
• Auto-power off effectively conserves battery life.
• Setup menu allows setting the number of calibration points, stability criteria, temperature unit,
date and time, etc.
• Reset function automatically resumes all settings back to the factory defaults.
• Expanded memory stores or recalls up to 500 data sets.
• USB communication interface is easy to transfer data to a PC.
• Multi-mode power scheme (batteries, power adapter, USB port) ensures the smooth operation
of the meter.
Model | Bante904P | |
Conductivity | ||
Range | 0 to 20.00, 200.0, 2000 µS/cm, 20.00, 200.0 mS/cm | |
Resolution | 0.001, 0.01, 0.1, 1, automatic | |
Accuracy | ±0.5% F.S. | |
Calibration | 1 to 5 points | |
Calibration Solutions | 10 µS / 84 µS / 1413 µS / 12.88 mS / 111.8 mS | |
Temperature Coefficient | 0.0 to 10.0%/°C | |
Pure Water Compensation | Yes | |
Reference Temperature | 20 / 25°C | |
Cell Constant | K=0.1 / 1 / 10 / Custom | |
TDS | ||
Range | 0 to 10.00, 100.0, 1000 ppm, 10.00, 200.0 ppt | |
Resolution | 0.01, 0.1, 1, automatic | |
Accuracy | ±1% F.S. | |
TDS Conversion Factor | 0.1 to 1.0 (default 0.5) | |
Salinity | ||
Range | 0.00 to 80.00 ppt / 0.00 to 42.00 psu | |
Resolution | 0.01 | |
Accuracy | ±1% F.S. | |
Resistivity | ||
Range | 0.00 to 20.00 MΩ | |
Resolution | 0.01 | |
Accuracy | ±1% F.S. | |
Dissolved Oxygen | ||
Range | 0.00 to 20.00 mg/L / 0.0 to 200.0 % saturation | |
Resolution | 0.01 / 0.1, selectable | |
Accuracy | ±0.2 mg/L / ±2.0 % | |
Calibration | 1 or 2 points | |
Pressure Correction | 60.0 to 112.5 kPa / 450 to 850 mmHg, manual | |
Salinity Correction | 0.0 to 50.0 g/L, manual | |
Temperature | ||
Range | 0 to 105°C / 32 to 221°F | |
Resolution | 0.1°C/°F | |
Accuracy | ±0.5°C / ±0.9°F | |
Calibration | 1 point | |
Calibration Range | Reading ±10°C/°F | |
Other Specifications | ||
Temperature Compensation | 0 to 100°C / 32 to 212°F, manual or automatic | |
Hold Function | Manual / Auto-read measurement endpoint | |
Stability Criteria | Low / High | |
Calibration Due Alarm | 1 to 31 days or off | |
Auto-Power Off | 10 / 20 / 30 minutes after last key pressed | |
Memory | Stores up to 500 data sets | |
Output | USB communication interface | |
Connector | 6-pin mini-DIN, 3.5 mm jack socket | |
Display | Custom LCD (80 × 60 mm) | |
Power Supply | 3 × 1.5V AA batteries or 5V DC power adapter | |
Battery Life | Approximately 150 hours without backlight | |
Environmental Conditions | 0 to 50°C / 32 to 122°F, relative humidity < 80% | |
Dimensions | 170 × 85 × 30 mm | |
Weight | 300 g |
Ordering Code | Meter Includes |
Bante904P-CN | CON-1 conductivity electrode |
DO100 dissolved oxygen electrode | |
TP-10K temperature probe | |
Conductivity standard solutions 84 µS/cm, 1413 µS/cm, 12.88 mS/cm | |
DO electrolyte solution | |
DO membrane cap | |
Electrode clip | |
Carrying case | |
Bante904P-UK
| K10 conductivity electrode |
DO100 dissolved oxygen electrode | |
TP-10K temperature probe | |
Conductivity standard solutions 84 µS/cm, 1413 µS/cm, 12.88 mS/cm | |
DO electrolyte solution | |
DO membrane cap | |
Electrode clip | |
Carrying case |
Items | Description |
CON-0.1 Conductivity Electrode | For measuring the pure water |
CON-1 Conductivity Electrode | For measuring the general water samples |
CON-10 Conductivity Electrode | For measuring the high conductivity samples |
DO100 Dissolved Oxygen Electrode | For measuring the DO and % saturation of oxygen |
TP-10K Temperature Probe | For temperature compensation and measurement |
Conductivity Standard Solutions | For conductivity calibration |
DO Electrolyte Solution | For filling the dissolved oxygen electrode |
DO Membrane Cap | For polarographic dissolved oxygen electrode |
USB Cable | For transferring data or connecting power adapter |
5V DC Power Adapter | For connecting external power source |
Ordering Code | Dimensions and Weights |
Bante904P-CN | 45 × 32 × 10 cm, 1.7 kg |
Bante904P-UK | 45 × 32 × 10 cm, 1.7 kg |