Ion Meters
Bante320 Portable pH/Ion Meter
Multiparameter portable ion meter, 2 to 5 points calibration, selectable concentration units, the meter is suitable for measuring pH, mV and ion concentration, accuracy: 0.5% F.S.
Ion Mode:
• Multiparameter portable ion meter is equipped with a backlit LCD display.
• 2 to 5 points calibration, including the selection of 8 concentration points.
• Automatic electrode diagnosis shows the calibration points and slopes.
• Direct ion concentration readout simplifies the measurement process.
• Selectable concentration units (ppm, mg/L, mol/L) and ionic valency.
pH Mode:
• 1 to 5 points calibration with automatic recognition for USA, NIST and DIN buffers.
• Automatic electrode diagnosis shows the pH slope and zero offset.
ORP Mode:
• 1 point offset calibration allows adjusting the displayed value to a known standard.
• Relative and absolute millivolt modes ensure the reliable ORP measurements.
Other Features:
• Automatic temperature compensation ensures accurate readings over the entire range.
• Auto-read function senses and locks the measurement endpoint.
• Calibration due alarm reminds the user to calibrate the meter regularly.
• Auto-power off effectively conserves battery life.
• Setup menu allows setting the pH buffer set, number of calibration points, resolution, stability
criteria, temperature unit, date and time, etc.
• Reset function automatically resumes all settings back to the factory defaults.
• Expanded memory stores or recalls up to 500 data sets.
• USB communication interface is easy to transfer data to a PC.
• Multi-mode power scheme (batteries, power adapter, USB port) ensures the smooth operation
of the meter.
Model | Bante320 | |
pH | ||
Range | -2.000 to 20.000 pH | |
Resolution | 0.001 / 0.01 / 0.1 pH, selectable | |
Accuracy | ±0.002 pH | |
Calibration | 1 to 5 points | |
pH Buffer Options | USA / NIST / DIN / 2 custom buffers | |
ORP | ||
Range | -1999.9 to 1999.9 mV | |
Resolution | 0.1 / 1 mV, selectable | |
Accuracy | ±0.2 mV | |
Calibration | 1 point | |
Measurement Modes | Relative / Absolute mV | |
Ion Concentration | ||
Range | 0.001 to 19999 (depending on the range of ISE) | |
Resolution | 0.001, 0.01, 0.1, 1, automatic | |
Accuracy | ±0.5% F.S. (monovalent), ±1% F.S. (divalent) | |
Calibration | 2 to 5 points | |
Calibration Solutions | 0.001 / 0.01 / 0.1 / 1 / 10 / 100 / 1000 / 10000 | |
Measurement Units | ppm, mg/L, mol/L, mmol/L | |
Temperature | ||
Range | 0 to 105°C / 32 to 221°F | |
Resolution | 0.1°C/°F | |
Accuracy | ±0.5°C / ±0.9°F | |
Calibration | 1 point | |
Calibration Range | Reading ±10°C/°F | |
Other Specifications | ||
Temperature Compensation | 0 to 100°C / 32 to 212°F, manual or automatic | |
Hold Function | Manual / Auto-read measurement endpoint | |
Stability Criteria | Low / High | |
Calibration Due Alarm | 1 to 31 days or off | |
Auto-Power Off | 10 / 20 / 30 minutes after last key pressed | |
Memory | Stores up to 500 data sets | |
Output | USB communication interface | |
Connector | BNC, 3.5 mm jack socket | |
Display | Custom LCD (80 × 60 mm) | |
Power Supply | 3 × 1.5V AA batteries or 5V DC power adapter | |
Battery Life | Approximately 150 hours without backlight | |
Environmental Conditions | 0 to 50°C / 32 to 122°F, relative humidity < 80% | |
Dimensions | 170 × 85 × 30 mm | |
Weight | 300 g |
Ordering Code | Meter Includes |
Bante320-CN | E201-BNC pH electrode |
TP-10K temperature probe | |
pH 4.01, 7.00, 10.01 buffer solutions | |
Electrode clip | |
Carrying case | |
Bante320-UK
| P11 glass pH electrode |
TP-10K temperature probe | |
pH 4.01, 7.00, 10.01 buffer solutions | |
Electrode clip | |
Carrying case |
Items | Description |
E201-BNC pH Electrode | For measuring the liquids |
E202-BNC pH Electrode | For measuring the semisolid and gel samples |
501 ORP Electrode | For measuring samples with weak redox potential |
502 ORP Electrode | For measuring samples with strong redox potential |
ISE-NH3 Ammonia Electrode | Range: 0.01 to 17000 ppm |
ISE-NH4 Ammonium Electrode | Range: 0.1 to 18000 ppm |
ISE-Br Bromide Electrode | Range: 0.4 to 81000 ppm |
ISE-Cd Cadmium Electrode | Range: 0.1 to 11200 ppm |
ISE-Ca Calcium Electrode | Range: 0.02 to 40100 ppm |
ISE-Cl Chloride Electrode | Range: 1 to 35000 ppm |
ISE-Cu Copper Electrode | Range: 0.06 to 6400 ppm |
ISE-CN Cyanide Electrode | Range: 0.03 to 260 ppm |
ISE-F Fluoride Electrode | Range: 0.02 to 1900 ppm |
ISE-I Iodide Electrode | Range: 0.06 to 127000 ppm |
ISE-Pb Lead Electrode | Range: 0.2 to 20800 ppm |
ISE-NO3 Nitrate Electrode | Range: 0.4 to 62000 ppm |
ISE-K Potassium Electrode | Range: 0.04 to 39000 ppm |
ISE-Ag Silver Electrode | Range: 0.01 to 107900 ppm |
ISE-Na Sodium Electrode | Range: 0.002 to 69000 ppm |
ISE-S Sulfide Electrode | Range: 0.003 to 32000 ppm |
pH Buffer Solutions | For pH calibration |
pH Electrode Storage Solution | For electrode maintenance and storage |
pH Electrode Cleaning Solution | For general cleaning |
pH Electrode Cleaning Solution | For removing the protein contamination |
Ion Standard Solutions | For ion concentration calibration |
Ionic Strength Adjusters | For adjusting the pH and background ionic strength |
USB Cable | For transferring data or connecting power adapter |
5V DC Power Adapter | For connecting external power source |
Ordering Code | Dimensions and Weights |
Bante320-CN | 35 × 10 × 30 cm, 1.5 kg |
Bante320-UK | 35 × 10 × 30 cm, 1.5 kg |